30 Dürr stomatologic Hygoclave touchpad cu ultima generatie de 18 litri

31,665.90 lei Inclusiv TVA

Hygoclave 30. Sterilisation made simple and reliable

Sterile instruments and expertise are a prerequisite for successful dental treatment. The Hygoclave 30 Class B Steam Sterilizer, provides the reassurance you need for a sustainably safe practice.

FEATURES

  • Short heating phase thanks to matched choice of material
  • Fast cycle time from 20 min onwards (drying included)
  • integrated fresh water quality tests
  • Protects the instruments by virtue of little thermal leaps
  • Low power consumption and excellent drying results due to a differentiated heating system
  • Automatic cleaning system
  • Diagnostic system for process evaluation and debugging
  • Elegant and functional design
  • Fast backup via USB interface and stick (included) 
  • Optional printer

PROGRAMMES:

ProgrammeProcess parametersLoad, max. loadTestType
Universal134 ºC, 5 min

3 Pre-vacuum phases.

Drying 10 min (6 min vacuum, 4 min aeration)
All packaged and unpackaged sterile materials

up to 134 °C 4 kg solid or 1.5 kg

porous instruments and tissues, or mixed
Helix TestB
Soft121 ºC, 20

3 Pre-vacuum phases.

Drying 11 min (7 min vacuum, 4 min aeration)
All packaged sterile materials up to 134 °C

4 kg solid or 1.5 kg porous instruments, or mixed
Helix TestB
Quick134 ºC, 3 min

1 Pre-vacuum phases.

Drying 3 min (2 min vacuum, 1 min aeration)
Non packaged, solid sterile materials

4 kg solid instruments
S
Special P1 prions134 ºC, 18 min

4 Pre-vacuum phases.

Drying 10 min (6 min vacuum, 4 min aeration)
Against Creutzfeld-Jakob and BSE pathogensHelix TestB
Special P2134 ºC, 5 min

4 Pre-vacuum phases.

Drying 13 min (8 min vacuum, 5 min aeration)
All packaged sterile materials up to 134 °C

4 kg solid or 1.5 porous instruments, or mixed
Helix TestB
Bowie-Dick Test134 ºC, 3,5 min

3 Pre-vacuum phases.

Drying 10 min (6 min vacuum, 4 min aeration)
For B&D Test (3M Comply TM, Code 1300)

B&D test pack or equivalent
B&D TestNo sterilization
Vacuum TestTemperature below 35 °CChamber emptyVacuum TestNo sterilization

The Hygoclave 30 programmes can be modified at any moment and individually adapted, making it easy and fast to deal with potential changes in instrument preparation regulation. These changes are validated afterwards on site.

TECHNiCAL DATA

  • Dimensions (L x H x W) in mm:  444 x 430 x 599
  • Chamber volume:  17.5 litres
  • Empty weight in kg:  55
  • Voltage in V:  230
  • Frequency in Hz:  50/60
  • Power in W:  1920
  • Average power in W:  1000
  • Load capacity (unpackaged instruments) in kg:
    • Solid, hollow instruments: 4
    • Porous materials: 1,5
  • Sound pressure (SPL) dB(A):  52

 

Cod Produs: HMED23.267-6050-01 Categorie:

Hygoclave 30. Sterilisation made simple and reliable

Sterile instruments and expertise are a prerequisite for successful dental treatment. The Hygoclave 30 Class B Steam Sterilizer, provides the reassurance you need for a sustainably safe practice.

FEATURES

  • Short heating phase thanks to matched choice of material
  • Fast cycle time from 20 min onwards (drying included)
  • integrated fresh water quality tests
  • Protects the instruments by virtue of little thermal leaps
  • Low power consumption and excellent drying results due to a differentiated heating system
  • Automatic cleaning system
  • Diagnostic system for process evaluation and debugging
  • Elegant and functional design
  • Fast backup via USB interface and stick (included) 
  • Optional printer

PROGRAMMES:

ProgrammeProcess parametersLoad, max. loadTestType
Universal134 ºC, 5 min

3 Pre-vacuum phases.

Drying 10 min (6 min vacuum, 4 min aeration)
All packaged and unpackaged sterile materials

up to 134 °C 4 kg solid or 1.5 kg

porous instruments and tissues, or mixed
Helix TestB
Soft121 ºC, 20

3 Pre-vacuum phases.

Drying 11 min (7 min vacuum, 4 min aeration)
All packaged sterile materials up to 134 °C

4 kg solid or 1.5 kg porous instruments, or mixed
Helix TestB
Quick134 ºC, 3 min

1 Pre-vacuum phases.

Drying 3 min (2 min vacuum, 1 min aeration)
Non packaged, solid sterile materials

4 kg solid instruments
S
Special P1 prions134 ºC, 18 min

4 Pre-vacuum phases.

Drying 10 min (6 min vacuum, 4 min aeration)
Against Creutzfeld-Jakob and BSE pathogensHelix TestB
Special P2134 ºC, 5 min

4 Pre-vacuum phases.

Drying 13 min (8 min vacuum, 5 min aeration)
All packaged sterile materials up to 134 °C

4 kg solid or 1.5 porous instruments, or mixed
Helix TestB
Bowie-Dick Test134 ºC, 3,5 min

3 Pre-vacuum phases.

Drying 10 min (6 min vacuum, 4 min aeration)
For B&D Test (3M Comply TM, Code 1300)

B&D test pack or equivalent
B&D TestNo sterilization
Vacuum TestTemperature below 35 °CChamber emptyVacuum TestNo sterilization

The Hygoclave 30 programmes can be modified at any moment and individually adapted, making it easy and fast to deal with potential changes in instrument preparation regulation. These changes are validated afterwards on site.

TECHNiCAL DATA

  • Dimensions (L x H x W) in mm:  444 x 430 x 599
  • Chamber volume:  17.5 litres
  • Empty weight in kg:  55
  • Voltage in V:  230
  • Frequency in Hz:  50/60
  • Power in W:  1920
  • Average power in W:  1000
  • Load capacity (unpackaged instruments) in kg:
    • Solid, hollow instruments: 4
    • Porous materials: 1,5
  • Sound pressure (SPL) dB(A):  52

 

WhatsApp chat Suntem pe WhatsApp!