Autoclav 8 litri clasa B cu USB si dubla inchidere de siguranta

8,821.47 lei Inclusiv TVA

Autoclave 8 litres class B with USB and double locking system.

Sterilisation programmes

ProgrammesTemp. (ºC)Pressure (KPa)

Sterilisation time

(Min)

Total time (Min)Type of materialMax. load (Kg)Max load per tray (Kg)
SOLiD134210414-25 Solid unwrapped2.000.60
1211102025-40
WRAPPED134210420-45 Solid unwrapped1.500.60
1211102030-50Solid or hollow simple wrapped

2.00

0.60
TEXTiLE134210825-50 Porous unwrapped0.500.15
Porous simple wrapped0.350.10
1211103030-55Porous doble wrapped0.250.10
Hollow simple wrapped1.500.30
Solid or hollow doble wrapped1.000.30
PRiON1342101830-50 Porous unwrapped0.500.15
Porous simple wrapped0.350.10
Porous doble wrapped0.250.10
Hollow simple wrapped1.500.50
Solid or hollow doble wrapped1.000.30
Test B&D1342103.515-35
Test HELiX1342103.515-25
Empty test17-20

 

Safety:

  • A cycle will not start unless the door is firmly closed.
  • Automatic system with double hydraulic safety locking device, prevents door opening while there is pressure in the chamber.
  • The safety valves prevent overpressure in the generator and the chamber.
  • A safety thermostat prevents overheating in the generator and the chamber.
  • An automatic safety lock prevents accidental opening of the door during the sterilisation process. An electricity protector interrupts automatically the power supply in case of a short circuit or if the power supplier is failing.
  • Failure alarm, indicates a cycle failure and specifies the error code.
  • Door alarm, indicates that the door is not locked properly.
  • Low water level alarm, indicates that the water tank is empty or too full.

Technical specifications:

  • Power supply: 220-240 VAC; 50/60 Hz; 10A
  • Chamber: 170 x 320 mm
  • Circuit voltage: F16A / 400V
  • Nominal power: 1500 VA
  • Sterilisation temperature: 121 ºC / 134 ºC
  • Capacity of the distilled water tank: 2.5 L
  • Working temperature: 5ºC / 40ºC
  • Working relative humidity: Max. 80%, non condensing
  • Overall dimensions: 414 x 365 x 530 mm
  • Net weight: 34.5 Kg
  • Max. noise level: <70 dB
  • Atmospheric pressure: 76 kPa / 106 kPa

Components:

  • Distilled water tank
  • LCD display
  • Control panel
  • Main power switch
  • Drain conector (distilled and used water tank)
  • USB port
  • Safety valve
  • Ventilation grid
  • Circuit breaker
  • Power cable
  • Rating plate

Accessories included:

  • Steriliser
  • USB
  • 2 instrument trays
  • Tray rack
  • Tray holder
  • Door adjustment tool
  • 2 draining hoses
  • Door gasket
  • User manual

Certification:

  • Directive 93/42/EEC on Medical Devices.
  • Pressure equipment Directive 97/23/EEC.
  • EN 13060 for small autoclaves.
  • EN 61326, EN 61000 Electromagnetic compatibility.
  • EN 61010-1, UL 61010-1 Safety requirements.
  • EN 61010-2-040, iEC 61010-2-040 Specific requirements for autoclaves used for treatment of medical equipment.

 AUTOCLAVE – step by step

1. Open the door, take the tools and accessories that are within the sterilisation chamber, remove the wrapper and clean them.

2. Connect the power cord to a suitable power source.

3. Connect the printer (optional). it is purchased separatelyref. 922-PRiNTER03).

4. Swith on: The main switch is located on the right bottom area in the front panel. Once activated, the LCD screen is on, where basic operation icons such as the position of the door, the water level, the sterilisation programme, date, time, etc. appear.

5. Fill tank with distilled water. Remove the top lid and fill, if you hear a signal, it means that you exceeded the permitted level of water in the tank, please stop immediately and drain the amount of water necessary for the signal off.

6. Preparation of material to be steri

Cod Produs: HMED23.922-STE-B8D Categorie:

Autoclave 8 litres class B with USB and double locking system.

Sterilisation programmes

ProgrammesTemp. (ºC)Pressure (KPa)

Sterilisation time

(Min)

Total time (Min)Type of materialMax. load (Kg)Max load per tray (Kg)
SOLiD134210414-25 Solid unwrapped2.000.60
1211102025-40
WRAPPED134210420-45 Solid unwrapped1.500.60
1211102030-50Solid or hollow simple wrapped

2.00

0.60
TEXTiLE134210825-50 Porous unwrapped0.500.15
Porous simple wrapped0.350.10
1211103030-55Porous doble wrapped0.250.10
Hollow simple wrapped1.500.30
Solid or hollow doble wrapped1.000.30
PRiON1342101830-50 Porous unwrapped0.500.15
Porous simple wrapped0.350.10
Porous doble wrapped0.250.10
Hollow simple wrapped1.500.50
Solid or hollow doble wrapped1.000.30
Test B&D1342103.515-35
Test HELiX1342103.515-25
Empty test17-20

 

Safety:

  • A cycle will not start unless the door is firmly closed.
  • Automatic system with double hydraulic safety locking device, prevents door opening while there is pressure in the chamber.
  • The safety valves prevent overpressure in the generator and the chamber.
  • A safety thermostat prevents overheating in the generator and the chamber.
  • An automatic safety lock prevents accidental opening of the door during the sterilisation process. An electricity protector interrupts automatically the power supply in case of a short circuit or if the power supplier is failing.
  • Failure alarm, indicates a cycle failure and specifies the error code.
  • Door alarm, indicates that the door is not locked properly.
  • Low water level alarm, indicates that the water tank is empty or too full.

Technical specifications:

  • Power supply: 220-240 VAC; 50/60 Hz; 10A
  • Chamber: 170 x 320 mm
  • Circuit voltage: F16A / 400V
  • Nominal power: 1500 VA
  • Sterilisation temperature: 121 ºC / 134 ºC
  • Capacity of the distilled water tank: 2.5 L
  • Working temperature: 5ºC / 40ºC
  • Working relative humidity: Max. 80%, non condensing
  • Overall dimensions: 414 x 365 x 530 mm
  • Net weight: 34.5 Kg
  • Max. noise level: <70 dB
  • Atmospheric pressure: 76 kPa / 106 kPa

Components:

  • Distilled water tank
  • LCD display
  • Control panel
  • Main power switch
  • Drain conector (distilled and used water tank)
  • USB port
  • Safety valve
  • Ventilation grid
  • Circuit breaker
  • Power cable
  • Rating plate

Accessories included:

  • Steriliser
  • USB
  • 2 instrument trays
  • Tray rack
  • Tray holder
  • Door adjustment tool
  • 2 draining hoses
  • Door gasket
  • User manual

Certification:

  • Directive 93/42/EEC on Medical Devices.
  • Pressure equipment Directive 97/23/EEC.
  • EN 13060 for small autoclaves.
  • EN 61326, EN 61000 Electromagnetic compatibility.
  • EN 61010-1, UL 61010-1 Safety requirements.
  • EN 61010-2-040, iEC 61010-2-040 Specific requirements for autoclaves used for treatment of medical equipment.

 AUTOCLAVE – step by step

1. Open the door, take the tools and accessories that are within the sterilisation chamber, remove the wrapper and clean them.

2. Connect the power cord to a suitable power source.

3. Connect the printer (optional). it is purchased separatelyref. 922-PRiNTER03).

4. Swith on: The main switch is located on the right bottom area in the front panel. Once activated, the LCD screen is on, where basic operation icons such as the position of the door, the water level, the sterilisation programme, date, time, etc. appear.

5. Fill tank with distilled water. Remove the top lid and fill, if you hear a signal, it means that you exceeded the permitted level of water in the tank, please stop immediately and drain the amount of water necessary for the signal off.

6. Preparation of material to be steri

WhatsApp chat Suntem pe WhatsApp!